Model: Concrete Mixer Bucket Part code: TS-MX06

Telehandler Concrete Mixer Bucket 600 L

This telehandler concrete mixer bucket mixes and pours up to 600 L (160 US gal) of concrete on site, with a hydraulic drive turning the drum at 20–40 rpm. It fits Telescro telehandlers from the T625-A up to the T1850, ordered with a pressure relief valve and usually a flow limiter. For a quote, send your model and hydraulic setup.
View Specs
Technical overview

Key Specifications

DatasheetTS-MX06

Concrete Mixer Bucket

Mixing Capacity
600 L160 US gal
Hydraulic FlowAt 20 MPa (2,900 psi) rated pressure
20–25 L/min5.3–6.6 US gpm
Mixing Speed
20–40 rpm
Bucket WeightEmpty
800 kg1,765 lb
Dimensions
1,030 × 1,930 × 850 mm41 × 76 × 33 in

Values as listed by the factory.

Mounting Type

Quick Coupler

Product Overview

Product Description

Mix and pour where a mixer truck cannot reach

The TS-MX06 concrete mixer bucket holds 600 L (160 US gal). A hydraulic drive turns the mixing drum at 20–40 rpm, and the telehandler lifts and places the batch where it is needed: footings, fence posts, a raised slab edge or a corner of the site with no truck access. It suits small batches and repair work rather than large continuous pours.

Hydraulic setup

The drum needs 20–25 L/min (5.3–6.6 US gpm) at a rated 20 MPa (2,900 psi). The Telescro telehandlers that take this bucket all run a higher auxiliary pressure, so it is ordered with a pressure relief valve and, where the pump delivers more flow, a flow limiter. Our guide to auxiliary hydraulic flow explains how to read your machine’s figures.

Machines and site use

It fits Telescro telehandlers from the T625-A up to the T1850, including the T1035 telehandler and the T1440 telehandler. See how a telehandler on a construction site shares lifting, loading and placing work, or compare construction telehandlers for your project.

The bucket weighs 800 kg (1,765 lb) before any concrete goes in, so check your load chart at the pouring reach. Send your machine’s auxiliary pressure and flow with the inquiry, and we specify the relief valve and flow limiter to match.

Other buckets and site tools are in the telehandler attachments catalog.

Options

Variants

Dimensions are length × width × height.

Part codeCapacityDimensionsWeightNotes
TS-MX06Concrete mixer bucket600 L160 US gal1,030 × 1,930 × 850 mm41 × 76 × 33 in800 kgMixing speed 20–40 rpm

Specifications

SpecificationValue
Rated hydraulic pressure20 MPa2,900 psi
Hydraulic flow20–25 L/min5.3–6.6 US gpm
Mixing speed20–40 rpm
MaterialQ355 steel (main structure)
Standard colorBlack
Fitment

Fits These Telescro Telehandlers

Find your Telescro telehandler in the table below.

1.2–2.5 t rated load

Telescro modelConcrete mixer bucketTS-MX06Notes
T625-A Compact Telehandler2.5t / 5.8mFitsPressure relief valve and flow limiter; check the load chart

3.5 t rated load

Telescro modelConcrete mixer bucketTS-MX06Notes
T4504 Telehandler3.5t / 4.5mFitsPressure relief valve
T3507 Telehandler3.5t / 7mFitsPressure relief valve and flow limiter
T735-A Agricultural Telehandler3.5t / 7mFitsPressure relief valve and flow limiter
T1035 Telehandler3.5t / 10mFitsPressure relief valve and flow limiter

4–5 t rated load

Telescro modelConcrete mixer bucketTS-MX06Notes
T1440 Telehandler4t / 14mFitsPressure relief valve and flow limiter
TH1840 Telehandler4t / 17.5mFitsPressure relief valve and flow limiter
T1850 Telehandler5t / 18mFitsPressure relief valve and flow limiter

Fits means it mounts on that model. Ask us means we check your machine and job before you order. The safe working load always depends on the machine's load chart.

Not sure it fits your machine?

Features

Configuration Options

Standard Configuration

  • Mixer bucket body with hydraulic mixing driveQ355 steel (main structure)
  • Black paint finishStandard color
Before You Order

Requirements, Options and Limits

What your telehandler needs, what you can add, and where this attachment should not be used.

Machine requirements

  • Auxiliary hydraulic circuit to drive the mixing drum20–25 L/min (5.3–6.6 US gpm)
  • Pressure relief valve when your machine's auxiliary pressure is above 20 MPa (2,900 psi)Fitted at order
  • Flow limiter when your machine supplies more than 25 L/min (6.6 US gpm)Fitted at order
  • Bucket weight of 800 kg (1,765 lb) plus 600 L (160 US gal) of concrete within your load chartCheck at the pouring reach

Available options

  • Coupler bracket to suit your telehandlerSend your machine model and coupler type

Limits of use

  • Machines that cannot supply 20 MPa (2,900 psi) and 20–25 L/min (5.3–6.6 US gpm)Ask us to check your hydraulics
  • Full bucket over the rated load at your reachPour smaller batches or reduce the reach
  • Large pours that need a continuous supplyUse a mixer truck or a concrete pump
Technical Data

Hydraulic Requirements

Pressure

20 MPa

2,900 psi

Flow Rate

20–25 L/min

5.3–6.6 US gpm

Important Safety Information

Check the load chart with the bucket full of concrete before lifting. Make sure the quick coupler is locked and the hydraulic hoses are fully connected before starting the drum. Keep hands and tools away from the drum while it turns, and depressurize the auxiliary circuit before connecting or disconnecting hoses. Never let anyone stand under a raised bucket.

Actual allowable load depends on the host telehandler and its load chart. Always operate within the host machine’s limits.

Get in Touch

Interested in this attachment?

Our engineers can help you verify compatibility with your machine and provide customized solutions.

Response Time

Within 2 hours

on business days